Published date: 10 July 2018
Last edited date: 10 July 2018
This notice was replaced on 5 February 2019
This notice does not contain the most up-to-date information about this procurement. The most recent notice is:
Future opportunity (published 5 February 2019, last edited 5 February 2019)
Closed future opportunity - This means that a potential contract has passed its approach to market date. A buyer can choose to consider any supplier interest or convert this notice into an opportunity ready for live procurement.
Contract summary
Industry
Imaging equipment for medical, dental and veterinary use - 33110000
Location of contract
London
Value of contract
£30,699
Procurement reference
LPPUCLPPS01-DN295389-98844739
Published date
10 July 2018
Approach to market date
15 June 2020
Contract start date
16 October 2017
Contract end date
15 October 2020
Contract is suitable for SMEs?
No
Contract is suitable for VCSEs?
No
Description
MRI No. 1
Quarterly Basis
• 1 off Climaveneta ACOB/09 Chilled Control Unit - 600510SC
• 1 off Filtrex PBH-420 Water filter
• 1 off Stokis GLP-008-M-PI-34-2059885 Heat Exchanger
• 1 off PCT S2XXJF-054THB-LMALE Ultrasonic Flow Meter
• 1 off Lowara 5HM06 S 07 M Pumps
• 1 off Aquilar AT-LDM-SM Leak Detection System
• 1 off Gresswell K98137 40MM G55 PRV (6BARG) Pressure
Relief valve
• 1 off Systemair KE50-30-4 Emergency Extract Fan
Annual Basis
• 1 off Gas Master - Gas Master 1 Oxygen Monitoring - Serial 04871
MRI No. 2
Quarterly Basis
• 1 off Daikin A/C Unit FWD 10/AT - MRI Exam Room
• 1 off Climaveneta ACO/09 Chilled water Upflow Unit - Serial No. 32047921
• 1 off Filtrex PBH-420 Water filter
• 1 off CW Flow Meter - S2XXJF-054-THB-LMALE
• 2 off Lowara 5HM06 S 07 M Pumps
• 1 off Vapac LE05PD Humidifier - Serial No. V51334
• 1 off Systemair AW Sileo 350 E4 Extract fan
• 1 off Stokvis Bare Plate Heat Exchanger GLP-008-M-4-PI-34-2059885
• 2 off Action Air Smoke Dampers
• 1 off Motorised Damper
• 1 0ff 5Kw Electric Heater
• Leak Detection System
• Chilled Water Pressure Relief valves
• JD Control Panel - Reference 3282
• Glass Traps
• All grilles, louvres & Diffusers
Annual Basis
• 1 off Gas Master - Gas Master 1 Oxygen Monitoring
• Provide with you submission a Method Statement for the Maintenance visit
• After the inspection please provide a full report with any recommendations you have
More information
Spend profile
Financial year | Budget |
---|---|
2017/2018 | £10,233 |
2018/2019 | £10,233 |
2019/2020 | £10,233 |
About the buyer
Contact name
Tony Chiassaro
Address
Level 2 Kenwood Wing
The Whittington Hospital
Magdala Avenue
N19 5NF
United Kingdom
Telephone
+44 2033161299
Website
Share this notice