Published date: 2 June 2023

Closed opportunity - This means that the contract is currently closed. The buying department may be considering suppliers that have already applied, or no suitable offers were made.


Closing: 16 June 2023, 11pm

Contract summary

Industry

  • Architectural, construction, engineering and inspection services - 71000000

Location of contract

M46JA

Value of contract

£110,000

Procurement reference

C505 EMERGENCY HARBOUR GENSET

Published date

2 June 2023

Closing date

16 June 2023

Closing time

11pm

Contract start date

1 June 2024

Contract end date

1 July 2025

Contract type

Supply contract

Procedure type

Competitive quotation (below threshold)

The buyer selects a group of potential suppliers to invite to tender.

This procedure can be used for procurements below the relevant contract value threshold.

Contract is suitable for SMEs?

Yes

Contract is suitable for VCSEs?

No


Description

Harbour and Emergency Diesel Generator Set
One (1) pc combined generator shall be provided, running on MGO only.
The Engine shall meet IMO TIER III requirements for emissions.
The generator shall supply the entire Vessel with power in emergency operation.
The generator shall be designed for standard requirements for an emergency generator.
The generator shall be designed for powering the vessel and/or the hybrid power bank batteries in
Harbour Alternator mode.
When in Harbour Alternator Mode, the engine shall have additional engine shut down in way of
High Jacket water temperature.
There shall be clear indication in the emergency generator room and on the ICAM on which mode
is selected.

The diesel engine shall be 4-stroke, turbocharged and inter-cooled with direct injection of liquid
fuel and electronic regulator. The rating shall be for continuous operation, fulfilling the e-load
calculation. The diesel engine shall be fitted with electrical/water standstill heating.
The diesel engine shall be with 24 VDC electric starter and a hydraulic starter for emergency start.
The generator shall be for marine use, brushless type generators with interference VDE 0875, class
N, or equivalent standards and the following particulars:

Voltage 3 Phase, 415 V, 50 Hz
Power factor Minimum 0.8
Speed TBC
Enclosure IP44, air cooled
Engine cooling Fresh water (Radiator with fan ventilation)
Alternator cooling Air cooled for marine operations
Insulation Class H (NEMA classification) or equivalent
Temperature rise Class F (NEMA classification) or equivalent
Thermal sensor One in each stator winding plus spare in each winding
Standstill heating Electrical/Water



The generator shall be equipped with:
Automatic Voltage Regulator, fuel oil tank with alarm, anti-condensation heater, and sensors for
vibration analysis monitoring that shall be integrated into the vessel's Condition Monitoring
system.
Local sensors: Lube oil pressure and temperature, fuel oil pressure, cooling water pressure and
temperature, battery status, and header tank level.


About the buyer

Contact name

ALBERTO CLEMENTE

Address

CALLE MUELLE, S/N
ALLANDE
M46JA
England

Telephone

+34 985636250

Email