Published date: 30 November 2020
This notice was replaced on 4 March 2021
This notice does not contain the most up-to-date information about this procurement. The most recent notice is:
Awarded contract (published 4 March 2021)
Closed opportunity - This means that the contract is currently closed. The buying department may be considering suppliers that have already applied, or no suitable offers were made.
Contract summary
Industry
Laboratory centrifuges and accessories - 42931100
Location of contract
Any region
Value of contract
£0
Procurement reference
tender_241324/907361
Published date
30 November 2020
Closing date
23 December 2020
Closing time
12am
Contract start date
26 January 2021
Contract end date
11 March 2024
Contract type
Supply contract
Procedure type
Open procedure (below threshold)
Any interested supplier may submit a tender in response to an opportunity notice.
This procedure can be used for procurements below the relevant contract value threshold.
Contract is suitable for SMEs?
Yes
Contract is suitable for VCSEs?
Yes
Description
General Requirements and Standards
APHA requires the supply and delivery of Two (2) Laboratory Refrigerated Bench Top Centrifuges and related accessories. APHA also requires extended warranty of two (2) years.
This Equipment is key in processing blood samples for diagnostic tests and preparation of samples for use in research projects, which are essential in fulfilling the obligations of research projects.
Specific Requirements
The Equipment requirements are detailed below: Two (2) Laboratory Refrigerated Bench Top Centrifuges, which must feature the following: - Capacity of 4L (4 x 1000ml)
- External Dimensions and weight: Height no greater than 380mm, width no greater than 760mm and depth no greater 690mm. Weight up to 120 kg.
- Corrosion-resistant, high-thermal conductivity, 304 grade stainless steel
- Maximal centrifuge speed of 15,200 rpm (25830 g; rotor dependent).
- Achievable run speeds of up to 6,000 rpm (7164 g) with a swinging bucket rotor.
- Minimum speed control accuracy of ±40 rpm.
- Time accuracy in one or both formats of hours/minutes or minutes/seconds (preferred)
- A temperature range between minus ten (-10) °C and plus forty (+40) °C.
- Accuracy control of +/- two (2) °C.
- A pre-Cooling function.
- Acceleration/Deceleration Rates up to nine (9) or ten (10).
- Facility to allow frequently used settings for users/applications to be pre-programmed and stored.
- Controls for setting speed, runtime, temperature and acceleration/deceleration rates. Display screen on which these parameters can be displayed.
- Viewing window for safe calibration of the instrument.
- Secure lid locking system with sensor to ensure lid is locked.
- Easy chamber access and quick installation of rotors.
- Low operational noise level (<64 dB with swinging bucket rotor at top speed).
- Compatibility with UK electric power provisions of 230 Volts and under 8 Amps current draw.
- Appropriate quality and safety standard markings as shown below:
➢ Conformité Européenne (CE) ➢ International Electrotechnical Commission safety standard for laboratory centrifuges IEC61010-2-020 ➢ Electromagnetic compatibility requirements which apply to electrical equipment for measurement, control and laboratory use EN61326).
- Rotor availability for purchase for at least ten (10) years post installation.
Further to the above the following accessories must be included with the Equipment for each of the two (2) centrifuges:
- Swing-out rotor (x1) - Buckets (x4). - Biocontainment lids (x4). - Adapters (x4) for 5/7 ml VAC blood tubes. - Adapters (x4) for 10/15ml VAC blood tubes. - Adapters (x4) for 15 ml conical tubes. - Adapters (x4) for 50 ml conical tubes. - Adapters (x4) for microplates.
More information
Attachments
-
- Project 29515 - Request for Quotation - Desktop centrfuges.pdf
- Tender notice
- n/a
Links
-
- help@bravosolution.co.uk
- Tender notice
- E-Tendering portal help
Additional text
-
Please note that Defra procurement uses an E-tendering system for Procurement activities. This is currently provided by Bravo Solutions. To access appropriate tendering and contractual documents, please access the E-Tendering portal at https://defra.bravosolution.co.uk", ensuring that your registration includes "Defra". If you have any problems with this system, please contact Bravo on their telephone helpline number 0800 368 4850 or by emailing them at help@bravosolution.co.uk.
About the buyer
Contact name
Defra Group Commercial
Address
Defra
London
SW1P 3JR
England
Share this notice
All content is available under the